SIKA 212 NON SHRINK GROUT

Sika

Part # 93309

SikaGrout 212is a non-shrink, cementitious grout with a unique two-stage shrinkage compensating mechanism, compensating for shrinkage in both the plastic and the hardened states. It is non-metallic, contains no chlorides and may be placed at various consistencies ranging from dry pack to fluid by simply adjusting the quantity of mixing water. Sold by the bag. Size: 25 kg (55 lb).


Description

Features and Benefits

  • Pre-blended for easy application and maximum field control. Just add water, mix and place.
  • Versatile, can be applied in any consistency from dry pack to fluid.
  • Non-corrosive does not contain chlorides.
  • Excellent pumpability - does not segregate even at high flow; no build-up on equipment hopper.
  • Low heat development.
  • Superior freeze/thaw resistance.
  • Ministry of Transport Ontario approval for use in grouting bridge bearings as well as anchor bars. (Reports MI-110, MI-120 respectively).
  • Meets Ontario Hydro specification M-690-87 for pumping through grout pump and hoses for a distance of up to 60 m (196 ft).
  • Ministère des Transports du Québec acceptance for grouting anchor bolts and reinforcing dowels in concrete.
  • Approved by the Alberta Ministry of Transportation
  • Meets H. A. Simons grout specification 1S-05.01 for grout types 1, 2a, 2b, 2c, 3 and 4.
  • Meets ASTM C 1107 for Grade C type grouts.

Applications

  • On grade, above and below grade, interior and exterior applications.
  • Structural grouting of column base plates, machine base plates, anchor bolts, bearing plates, bridge seats, precast wall panels.

Limitations

  • Maintain wet grout, ambient and substrate temperatures between 5° - 32°C (41° - 89°F) for a period of 72 hours after placing, unless using Sikacem® Accelerator in mix (refer to Technical Data section).
  • SikaGrout® 212 and 212 SR must be protected from freezing during setting.
  • Minimum application thickness (neat without additional aggregate): 25 mm (1 in).
  • Maximum application thickness (neat without additional aggregate): 150 mm (6 in). Deeper applications are possible with the addition of suitable aggregate. Please contact Sika’s Technical Services.
  • For anchor bolt/dowel grouting, hole diameter should be 25 mm (1 in) greater than bar diameter.
  • Anchor bolt/bar holes should be pre-dampened for a period of 1 hour prior to grouting. Holes must be in saturated surface dry (SSD) condition at time of grouting.
  • Do not use as a patching or overlay mortar or in unconfined areas.